winIPRO version info

 

The winIPRO version info gives an overview about the latest improvements of your current winIPRO version. If a new winIPRO version is available for online maintenance, you can find the version info of the update at external link (www.ipro.de)http://static.ipro.de/gb/Version.htm

 

Version 8.1.44.0 | 8.2.44.1 | from 12.02.2020

 

8.1

8.2

Lens Ordering System

  x
New: LensNext (B2B E-Mail).
     
   
New: Signet Armorlite (B2B Webservice).
  x

From 1.12.2019, this is the only official way for online ordering

     

8.1

8.2

Lens Consultation Interface

Essilor OpsysWeb
  x

If no centration values were recorded in the order and the centration mode is y', the values were not converted correctly. Prerequisition for importing is a form and box height, otherwise a coversion is not possible.

     
General (also for centration program interfaces)
  x

If the same interface was activated for two buttons, but with different suppliers, sometimes the wrong supplier was selected when the button was pressed in an order window. Fixed. Also, the selected supplier is now shown in the tooltip.

     

8.1

8.2

Lens Price Lists

   
Calculation
  x

The column 'Marketing description' didn't show information for lenses and surcharges. Fixed.

     

8.1

8.2

Patient Card File

   
New: Responsible attendant
  x

The staff member responsible for this patient can now be entered in the patient card file

     
   
Remark field
  x

The remark fields below the email-address can now hold 79 characters.

     

8.1

8.2

Case History

   
All case history sheets in the online data service
  x All available case history sheets can now be downloaded from the online data service without additional costs.
  x The sheets in the new design can be evaluated using patient promotion and statistics.
     

8.1

8.2

Contact Lenses

   
New: Indication per eye
  x

The indication can now be entered for each eye separately, also in the EyeExam report.

     
   
New: Mono-vision
  x

New TAB "Usage" at refractions for mono-vision adaptations.

     
   
New: Lab
  x

In CL-Procedures a new tab is available for values measured in the LAB

     
   
New: Free Lens acceptance
  x

In CL-Procedures, CLs can now be freely accepted from all previous orders and procedures.

     
   
New: APEX (Radii)
  x

APEX degree and position can now be entered in the 'CL-Radii' window.

     
   
Complementary refraction
  x New: New field for entering the binocular visus and distance.
     
   
Remarks in procedures
  x

The text-block management for the procedure remarks (subjective, objective, plan, lab) has been separated. Each text-box now has individual text-blocks. Default is the former common text-blocks.

     

8.1

8.2

Stock Management

   
Sales Prices
  x Sales price input now up to 30,000.--.
     
   
Barcode
  x Barcode-Type GTIN14 now supported.
     
   
Calculators
  x New: Calculators for calculating purchase prices based on list prices
     

8.1

8.2

Workshop Devices

  x
New: Huvitz HFR 8000 (Tracer).
  x
New: Huvitz ZFR 500 (Tracer).
  x
New: Weco T6 (Tracer).
     

8.1

8.2

Appointment Diary

   
Click2Date
  x

For the automatic confirmation emails, all text-parameters of the appointment are now available.

  x

Appointment requests will be assigned to an existing patient from the patient card file, if first and surname plus either phone, email or DOB are identical.

     
   
Send Appointment as Email
  x

The title of the appointment, which is send as an email-attachment, is composed of the appointment activity and subject. Especially at Click2Date-Appointments, which are created with the automatic subject 'Online-Appointment', the title now shows e.g. "Spectacle consultation | Online-Appointment".

     

8.1

8.2

System

   
Delete historical data
x

Program added to delete old patient data as required by GDPR.

     

8.1

8.2

Maintenance

   
Error Mesages
x

Informative error message if no update is avaialble for the required version.

 

Version 8.1.43.0 | 8.2.43.1 | from 18.09.2019

 

8.1

8.2

Lens Ordering System

Hoya (Webservice)
  x

Connection to lens-code conversion webservice changed to HTTPS (https://www.hoyailog.com).

x

In CH/AT/DE the order text is ignored, input field deactivated for theses countries after consultation with Hoya.

     
   
General (B2B-Format)
  x

Ordering data are no longer recorded in the IPROSYS\Client\...-directory but can be found in the Archiv-directory after ordering.

     

8.1

8.2

Lens Consultation Interface

Hoya Hoyailog
  x

After consultation with Hoya, the HoyaiLog-Webpage will now be started with the appropriate country-specific webpage in the browser, e.g. https://de.hoyailog.com in  Germany.

  x

Interface changed from HoyaiLink to HoyaWebiLink, as iLink is switched off by Hoya at the end of 2019.

     

8.1

8.2

Patient Card File

   
New: TAPI-interface for CTI
  x

If a CTI-software has been installed on a computer, the patient's phone number can be dialled directly from the patient card file with one mouse-click.

     
   
Postcoder UK
  x

Interface to UK-Postcoder didn't work correctly in a terminal-server environment. Fixed.

     

8.1

8.2

Contactlinse

   
New Procedure
  x

When entering a new procedure, the texts at "Results subjective", "Results objective" and "Plan" will no longer be copied over.

     

8.1

8.2

Appointment Diary

Click2Date
  x

In C2D, only those activities are available which have at least one room assigned in a branch which is managed by C2D.

  x

If 'any employee' is selected during appointment request, 'any employee selected' will be shown in the appointment's remark field.

     
Appointment View
  x

Appointment tool-tip now also shows patient age and sex, if known.

  x

If the filter 'Branch and Group' and 'show all employees present' were set, all employees of the group were shown, even if the branch didn't fit. Fixed.

     
Holiday lock Drag & Drop / Copy & Paste
  x

Branch is set to the first branch assigned to the employee, if available. Otherwise to the standard branch.

     

8.1

8.2

Reminder

   
Export
  x

Prior to sending out, the age of the files is checked. If the are 3 days old or older, an additional warning is displayed.

 

Version 8.1.42.0 | 8.2.42.1 | from 18.03.2019

 

8.1

8.2

Lens Ordering System

  x
New: OGA (B2B Webservice)
     
Nika (B2B E-Mail)
  x

Facette-position with value entry in mm from front edge released; Groove depth and width released; Edge break blocked; Everything in consultaton with the supplier.

  x

Prism. Height adjustment blocked, in consultation with the supplier.

     
   
Essilor (B2B Webservice)
  x

From 1.12.2018, customers from Flanders order at Essilor-Belgium.

     
   
Hoya HoyaiLog
  x

Authentification server changed from www.hoyanet.net (HTTP) to www.hoyacas.com (HTTPS).

     
   
Optix Direct (B2B Webservice)
  x

Replaces Optix Direct (B2B E-Mail)

  x

Additional fields released in additional supplier order data window, in consultation with the supplier.

     

8.1

8.2

 CL Ordering System

Cooper (Webservice)
  x

 'Material' field is no longer transferred to supplier.

     

8.1

8.2

Centration Devices Interface

Essilor VisiOffice, Optovision VET, Rodenstock ImpressionIST, VisuReal
  x

Patient address, Phone, Fax and patient remark are no longer transferred to the third-party program for data protection reasons.

     

8.1

8.2

Patient Card File

Patient Input
  x

Bank details: Update of  BIC-list.

     

8.1

8.2

Lens Consultation Interface

Essilor OpsysWeb
  x

From 1.12.2018, customer from Flanders order at Essilor-Belgium.

     
Hoya Identifier
  x

Authentification server changed from www.hoyanet.net (HTTP) to www.hoyacas.com (HTTPS).

     

8.1

8.2

Appointment Diary

   
Click2Date-Activity
  x

For Click2Date-activities, a patient assignment must be possible.

     
Calling up from card file / order
  x

New setting for start-view, if the diary is opened from the card file or an order to make an appointment. Option for day or week view.

     
Appointment entry
  x

On changing the appointment's activity, the room will not be changed if the room is assigned to the new activity.

     
Lock entry
  x

During new lock entries from the holiday monthly view, the transfer and preset of the employees sometimes didn't work. Fixed.

     

8.1

8.2

Eye Exam Devices Interface

   
Rodenstock DNEye Scanner
  x

Sometimes wavefront-measurements were also shown during topography data import into a CL-order. Fixed.

     

8.1

8.2

System

   
Data backup
  x

Sometimes the data backup crashed near the end if very large files were processed. Fixed.

     
   
Event protocol sending to our support
  x

During sending of several emails, an error messages was displayed for the first ones although the emails were sent successfully. Fixed.

8.1

8.2

Insurance Card Reader

   
uTrust
  x

Identiv uTrust 2700 F/R now supported.

     

 

Version 8.1.41.0 | 8.2.41.1 | from 12.11.2018

 

8.1

8.2

Lens Ordering System

  x
New: Signet Amorlite (B2B Webservice)
  x
New: Optix Direct (B2B Email)
     
Essilor (B2B Webservice)
  x

new HTTP-Server: h1.essilor.tradexpressondemand.com

     

8.1

8.2

Patient Card File

Patient Input
  x

If, during a new patient entry in the search patient window, the window is closed with "Cancel", the already entered details/fragments are now deleted. Up to now, fragments that didn't comply with the required fields setting, could be stored in this way. This route has now been closed.

     

8.1

8.2

Hearing Aids

   
Ear moulds
  x

New: Integration of Smartoptics ear scanners

     

8.1

8.2

Appointments

   
Click2Date (Online Appointments)
  x

The branch addresses are now transferred with the branch data. These are used for the geodata in the Google-Maps window.

  x

It can now be set for each workstation, whether or not the table with the Click2Date-appointments shall be shown.

     
Day and week view
  x

If grouping by room has been selected, columns containing appointments without room assignment had the column header "without".
Now these columns are named according to the branch designation in brackets.

     
Collision check
  x

Sometimes, a collision warning for fictional rooms was displayed for appointments with a branch but no room. Fixed.

     

8.1

8.2

System

   
Data backup check
  x

If a successful data backup has not been made for more than 7 days, a warning will be displayed.

  x

Also, a warning will be displayed from time to time, if the automatic data backup is run in the mode "Ipro data w/o Blobs". In this mode, documents, images, videos, measurements etc are not backed up. In case of an error, data can be lost.

   
Please take care to back up your complete data regularly.
     

Version 8.1.40.0 | 8.2.40.1 | from 26.06.2018

 

8.1

8.2

Lens Ordering System

Zeiss (B2B Webservice)
  x

Option added to send patient name in additional lens order data.

  x

If drill holes were transferred without diameter, an error message was displayed. Error cause fixed.

     
Nika (B2B E-Mail)
  x

Option for 2nd pair orders added in additional lens order data.

     
Rodenstock (B2B Webservice)
  x

An individual pupillary diameter measured by the Impressionist4, is now saved and sent with the order.

  x

Support for new surcharge DN2 added.

     

8.1

8.2

Patient Card File

Promotion, Opt-In-Preferences
x x

The value for 'Health data' in the Opt-In-Preferences was not correctly saved sometimes. Fixed.

     
Deleting patients
  x

During patient deletion with transfer of orders to another patient, the contact details (mobile, email) of the patient to be deleted can now also be transferred to the other patient.

     

8.1

8.2

Glasses

Text-parameters lenses
  x

Parameters /LRSPVAL/ and /RRSPVAL/ added for the recommended sales price of lenses. The RSP for the lens plus surcharges from the current price list will be shown.

     
   

Lens Consultation Interface

Rodenstock WinFit
Rodenstock Consulting
  x

Import of main viewing distance. Near corrected.

  x

New symbols for interface buttons.

     
   
Zeiss i.com mobile
  x

Eye height and width will no longer be imported if a traced form has already been saved in the order. DBL in this case only, if the field is still empty.

     
   

Workshop Devices

   
Briot / Weco
  x

Connection via LAN for newer Briot / Weco devices added.

     
   

Appointment Diary

  x
New: Click2Date (Online Appointments)
     
Appointment view
  x

Email address in the appointment will be marked with colour if invalid.

     
ICS-Export
  x

Deletion of appointments / Locks sometimes didn't work. Error removed.

     
   

Eye-Exam Interface

   
Rodenstock DNEye Scanner
   
Zeiss i.Profiler
  x

Surname filter now possible.

  x

Date of birth can now be shown, if available.

     
   
Rodenstock DNEye Scanner
  x

The distance of cornea to lens is now saved as part of the DNEye-measurement data and will be sent with the order.

  x

Support for DNEyeScanner Software Version 3 added.

  x

The measurement data type is now shown.

  x

Import of topography-data in CL-order and Eye-Exam report, if DNEyeScanner has been updated to Version 3.x.

     

 

Version 8.1.39.0 | 8.2.39.1 | from 16.01.2018

 

8.1

8.2

Lens Ordering System

Mailshop (B2B Email)
  x

B2bOptic format changed from version 1.5.1 to 1.6.1 at the supplier's request.

  x

Multiple orders activated at the supplier's request.

     
Zeiss i.Com
Zeiss i.Com mobile
Zeiss VisuStore
  x

New symbols for the interface buttons.

     
  x
New: m-lens (B2B EMail)
     
Eyetech (Eyeline)
x x

New server-address included.

     
EMO Essilor (B2B Webservice) (Hungary)
  x

New order input field NVB.

  x

Order input field Head-Eye-Quotient removed at the supplier's request.

     

8.1

8.2

CL Ordering System

Bach, Conil, MarkEnnovy, Menicon
  x

New supplier symbols.

     

8.1

8.2

CL Replacement Schemes

   
Sauflon
  x

Support for new SFTP-server of CooperVision added

     

8.1

8.2

Reminder

   
Reminder input in patient card file
x x

Multiple identical reminders cannot be entered for one patient anymore.

     

8.1

8.2

Appointment Diary

Appointment sending by email
  x

The emails are now displayed correctly by Outlook, Thunderbird, iOS, Android, Windows Mail, Windows Calendar, Google Mail and Google Calendar, and the appointments accepted, if applicable.

  x

During sending from the list view, text parameters sometimes were not replaced. Fixed.

     

 

Version 8.1.37.0 | 8.2.37.1 | from 15.05.2017

 

8.1

8.2

Lens Ordering System

Eyetech (Eyeline)
x x

New server-address added.

     
Essilor (B2B Webservice)
  x

New ordering parameter NVB (near vision behaviour).

x x

Following a request by the supplier, "Min. lens thickness at drill hole" cannot be entered anymore for Precal.

     
Reize (B2B Webservice)
  x

New ordering parameter "Size".

     
Hoya (Webservice)
x x

If the Hoya-server reports several errors for one order, these are now displayed in list form.

     
Rupp Hubrach (B2B Webservice)
  x

New ordering option "Preference" with value-input (e.g. 50, 75, 100) for EyeScreen-lenses.

     

8.1

8.2

CL Ordering System

   
Johnson (Webservice)
x x

Support for the countries UK and LUX.

     

8.1

8.2

Lens Price Lists

Lens price list loading
x x

Loading of lens price lists in the standard SF 6.10.3 now possible.

     

8.1

8.2

Lens Consultation Interface

Zeiss VisuStore
  x

After ordering in VisuStore, the order status cannot be retrieved from Zeiss webservice for up to 60 seconds. In this case, winIPRO assumes the ordering has been successful and sets the order to "ordered".

     
Essilor OpsysWeb
  x

New ordering parameter NVB now supported.

     
Zeiss i.Com Mobile
  x

Can now be used without the ordering system "Zeiss (B2B Webservice)".

  x

FrameFit is now imported as a measurement value.

     
Zeiss i.Com
Zeiss VisuStore
Zeiss Logon
R+H Nuvola
Rodenstock Winfit
  x

Frame height, width and DBL are not imported anymore, if a traced form or rough form has previously been entered in the order, and the form has not been overwritten by an equivalent form.

     
Zeiss VisuStore
Zeiss Logon
  x

2nd pair info are now sent.

     

8.1

8.2

Centration Interface

Essilor VisiOffice
  x

Import / Export of parameter NVB added.

     

8.1

8.2

Patient Card File

Contact details
  x

Symbol for 'SMS' replaced by balloon, to better distinguish it from '@' for email.

     

8.1

8.2

Eye Exam Report

   
History and Symptom sheets
  x

Name additions are now also shown with the patient name.

     

8.1

8.2

Internet Connections

   
Email-sending
  x

In some email-clients, the text-only part of HTML-mails has been shown as well, fixed.

     

8.1

8.2

Online Data Service

     
CL-Catalogues
  x

CL-catalogues from the area 'w/o prices' contain this description now also in their names, to better distinguish them from the ones with prices in the collective areas (Favourites, Downloads, News).

     

8.1

8.2

Password System

Password input, User log-on
  x

The windows for password input and user log-on now close automatically after 4 minutes of inactivity. This prevents that automatic processes have to wait forever. The window will close after 4 minutes with "Cancel".

     

 

Version 8.1.36.0 | 8.2.36.1 | from 13.02.2017

 

8.1

8.2

Lens Ordering System

IGA (B2B E-Mail)
x x

Option "Multiple Order" activated following the supplier's request.

     
OPS Optics (B2B E-Mail)
x x

Following the supplier's request, the file sent now has a different name.

     
Knecht & Müller (B2B E-Mail)
Knecht & Müller (WinWorld 3)
x x

Preference activated by supplier, according to current price list.

     
Rupp+Hubrach (B2B Webservice)
  x

Changeover to new side-independent field for handedness.

     
De Ceunynck (B2B Webservice)
  x

New field for handedness added, after consultation with supplier.

     

8.1

8.2

Lens Consultation Interface

Zeiss Logon
  x

After closing Logon, a query about importing the order data will now be displayed.

     
x
New: Zeiss VisuStore
     

8.1

8.2

 Patient Card File

   
New entry (Belgium only):
  x

Insurance status and Insurance company will be automatically set during new patient entry.

     

8.1

8.2

Contact Lenses

   
New Procedure
  x

If a new procedure shall be recorded as a delivery, but the last procedure hasn't been a delivery (e.g. recheck), a query is now displayed, asking if the last delivery should be taken as the preset for the new procedure.

     

8.1

8.2

 Eye Exam Report

   
Measurement Type Tonometer
  x

New field Corneal Thickness.

     

8.1

8.2

 Eye Exam Report Instruments Interface

Tonometer Essilor Wave Analyser
   
Tonometer Visionix VX 120
   
Tonometer Nidek NT 530P
  x

Corneal thickness is now transferred from the device

     
x
New: Autorefractor NIDEK AR-1S
     

8.1

8.2

Internet Connections

Error messages
  x

Detailed error messages are now displayed on errors regarding HTTP-, FTP- and SFTP-connections.

     
Email Test-Function
x x

Error removed in the SMTP/POP3 test function: At POP3, the error message from SMTP was displayed, even when no error was detected at POP3.

     

8.1

8.2

Online Data Service

CL-Catalogues / Look4
  x

CL-catalogues which are available at Look4, now have to loaded directly from there, they are not available at IPRO anymore. Therefore, previously saved favourites may get lost, but can be saved again. New: Different country-versions of the same catalogue are now distinguished.

     

8.1

8.2

Master Data

   
Suppliers / Printing
x x

If the text in the remark field was longer than 2000 characters, the text was cropped and the program crashed during the next start-up. Now, a maximum of 4000 characters can be entered. Program will not crash anymore on reaching the limit.

   
Branches / Form-printing codes
x x

New printing codes for /FRANCHISE/ and /BRATEXT11/ to /BRATEXT20/

     

 

Version 8.1.35.0 | 8.2.35.1 | from 05.12.2016

 

8.1

8.2

Lens Ordering System

Zeiss (B2B Webservice)
  x

Option added to change the HTTP-Port from 80 to 443 in the supplier master data. This will encrypt the data transmission to Zeiss.

     
Austrian Optic (B2B Webservice)
x x

Glazing orders now available.

     

8.1

8.2

CL Ordering System

   
MPG&E (Webservice)
x x

After MPG&E modified their webserver, the winIPRO ordering system couldn't communicate with it anymore. winIPRO ordering system has now been adapted accordingly and can access the server again.

     

8.1

8.2

Lens Consultation Interface

Zeiss Logon
  x

Customer number and password are now taken from the supplier master data, and not from the interface preferences anymore.

     

8.1

8.2

Patient Card File

   
CL-, HA-Tabs
  x

Multi-digit combined order/procedure-numbers are now displayed in a smaller font instead of being cropped.

     
   
Priority messages
  x

Sometimes, priority messages from the same patient card file on the same workstation were displayed, if the user clicked multiple times and very fast in the card file, and many tabs are displayed in the card file. Problem fixed.

  x

... or at least alleviated.

     

8.1

8.2

Eye Exam Report Instruments Interface

   
Tonometer Essilor Wave Analyser
   
Tonometer Visionix VX 120
  x

Intraocular pressure is now corrected by the corneal thickness.

     

8.1

8.2

Task Scheduler

Changes
  x

If changes are made in the task scheduler, the configuration is now re-loaded at all running workstations, not only at the workstation, where the change has been made. Affects only those workstations that run winIPRO all the time. All others will reload the configuration during winIPRO start-up anyway.

     

8.1

8.2

Online Data Service

CL-Catalogues / Look4
  x

CL-catalogues, which are available at Look4, will not be cared for at IPRO anymore. Instead, the winIPRO Online Data Service will load them directly from the Look4-server via a standard access. In the Online Data Service window, you will find them in the "CL-Look4 General" directory.

x

Customers with individual Look4-access data will still have additional access to their individual catalogues in the directory "CL-Look4 own brands".

x

New: Look4 Frames catalogues.

     

8.1

8.2

winIPRO Webbrowser

  x

Sometimes, the webbrowser didn't remember the last window size and position. Error removed.

     

8.1

8.2

Data Backup

   
Write error on USB-devices
  x

If, on a USB-device, iprosave-directories can be deleted but not newly created, the cause may not necessarily be a hardware failure, but anti-virus programs and caching procedures can also block it. In this case, the access to the device will be re-tried several times automatically.

     

 

Version 8.1.34.0 | 8.2.34.1 | from 19.09.2016

 

8.2

Branch networking

x

New: Networking of print-profiles, text-forms and SMS/Email texts.

x

New: Networking of SMS/Email configurations.

x

New: Networking of patient contact marks.

     

8.2

SMS

x

New: SMS-sending via webservice. Status view and info in the patient contacts and the order status control list "SMS Status", as well as automatic status update via winIPRO task scheduler.

     

8.1

8.2

Ordering System Lenses

x x
New: DeCeunynck (B2B Webservice)
x x
New: Pullmann (Pullmann Client)
     

8.1

8.2

Patient Card File

   
Address input
x x

Age is shown even for invalid date of birth 29.2. in non-leap year.

x x

Post code for Romania now 6-digits.

     

8.1

8.2

Patient promotion

Lists
x x

The Address/Country column can now be edited. Attention: Please take care that the postcode format fits the country! Otherwise you may not be able to enter the postcode in the address input window anymore.

     

8.1

8.2

Stock

   
Stock lists
x x

New booking option "Breakage" available in manual lists and evaluation lists.

     
   
Electronic delivery notes
x x

Delivery notes from Charmant, Menrad, DeRigo, Visibilia and Marchon can now be loaded into the system.

     
   
Sales report
x x

Sales reports can now be created for Eschenbach, DeRigo, Charmant, Menrad.

     

8.1

8.2

Branch networking

Rights
  x

New rights area "Contact marks".

  x

New rights area "SMS-configuration".

  x

Rights area "Word processor" extended: Print-profiles added

     

8.1

8.2

Workstation profiles

Preferences
x x

During preferences-changes, a warning was displayed, that these preferences come from a profile, and will be overwritten during next Ipro-start, even if the profile in question hasn't been assigned to the current workstation. Error removed.

     

8.1

8.2

Patient loyalty

Loyalty Lab
x x

The patient data country will not be fixed to DE or NL anymore, instead, the appropriate ISO-code will be exported. Changes made after consultation with Loyalty Lab..

     

 

Version 8.1.33.0 | 8.2.33.1 | from 06.06.2016

 

8.1

8.2

Ordering System Lenses

     
x x
New: OPS Optics (B2B E-Mail)
Reizen (B2B Webservice)
x x

Following the supplier's request, base curve input has been locked.

     
Omega Optix (B2B E-Mail, B2B Webservice)
x x

After consultation with the supplier, the distance centration point distance z will be sent for bifocal lenses too.

     
Frametec (B2B E-Mail)
x x

Following the supplier's request, "z" instead of "q" will be transferred for bifocal lenses.

     

8.1

8.2

Lens Consultation Interface

x x
New: Zeiss Logon
     
   
Hoya HoyaiLog, Hoya Identifier
x x

Import of decentration data in Polar view.

     
   
e-cado + Vinzent
x x

Eye-rotation point distance b' is now imported.

     

8.1

8.2

Patient Card File

   
Address input
x x

After "Country" input, the cursor now moves to the postcode automatically.

     

8.1

8.2

Appointment diary

ICS-Export
  x

Appointments are now exported with correct time-zone information. The current time-zone is automatically determined, but can be changed in the diary options.

 

Version 8.1.32.0 | 8.2.32.1 | from 12.04.2016

 

8.1

8.2

Ordering System Lenses

   
Schulz (B2B Webservice)
Austrian Optic (B2B Webservice)
x x

New field "Inset" added after released by the lens suppliers.

     

8.1

8.2

Ordering System CL

   
Bausch (Webservice)
x x

Orders are now sent in one file as Bausch cannot combine several files. For the time being, the status check had to be switched off because of that.

     

8.1

8.2

Lens Consultation Interface

   
Zeiss i.Com mobile
x x

Measurements of the type "Current glasses" (CurrentRX) are not included in the "prescription" tab anymore.

     

8.1

8.2

Patient Card File

   
Patient Stoplight
  x

Symbols have been adapted to the new design.

  x

New: It is now possible to define own colours for the symbols.

  x

New: In addition to the winIPRO Stoplight-symbols, any symbol from installed fonts can be used.

     
   
Design
  x

Order-symbols for "Quotation", "Void", "Picked-up", "Paid" etc. have been adapted.

  x Symbols in the "Find patient" window have also been adapted to the new design.
     

8.1

8.2

Contact Lenses

iProfiler / Data transfer
x x

Newer instruments do not necessarily still have the assignment 1=h, 2=v . During data transfer, the assignment is now done depending on the axis position. This modification has already been added to the EyeExam Report as well.

     

8.1

8.2

Appointment Diary

ICS-Export
  x

New: Export of appointments per employee in individually set intervals.

  x

New: Format settings for the ICS-export can be individually set and adapted.

  x

New: Automatic upload of the appointments to the iConnect Calendar Cloud and import to iPhone, Android smartphone or Outlook.

     

8.1

8.2

Print-profiles

    Print-profiles are automatically included in version 8.2, in version 8.1 only after activation.
(x) x

New: Extension of order printing by additional fields and functions.

(x) x

New: Option to set up print-profiles which control the print-dialogue and pre-select the forms from the print-profile according to the filters set.

     

8.1

8.2

Lists

   
Design
  x Order symbols and list symbols adapted to the new design.
     

8.1

8.2

Documents Management

  x

New: The documents management is now accessible from all order types in the print-dialogue, documents and printouts can be saved directly with the order.

  x New: Document template as Word-file with patient and branch text parameters.
     

8.1

8.2

Eye Exam Report - Instruments Interface

x x
New: HS Visutron Touch
x x
New: Nidek NT-530P
     

8.1

8.2

Workshop Devices Interface

x x
New: Weco C.6
x x
New: Briot Attitude
     

8.1

8.2

Patient Loyalty Interface

   
Loyalty Lab
x x

Customer numbers from suppliers are not cut off after 6 digits or filled up with 0 anymore.

     

 

Version 8.0.31.0 | 8.1.31.1 | from 08.02.2016

 

8.0

8.1

Ordering System Lenses

   
Mailshop (Edifact via email)
x x

New email-address: ipro-Bestelldaten@dao-ag.de. Please change in supplier's master data.

x x

New name: Deutsche AO (Edifact via email)

     

8.0

8.1

CL Ordering System

  x
New: Bach (Webservice)
  x
New: Conil (Webservice)
  x
New: Conta (Webservice)
  x
New: Mark Ennovy (Webservice)
  x
New: Menicon (Webservice)
  x
New: Procornea (Webservice)
     

8.0

8.1

Lens Consultation Interface

  x
New: Zeiss i.Com mobile
     
   
Essilor OpsysWeb
  x

Send centration point distance "z" for Bifo/Trifo.

     

8.0

8.1

Patient Card File

   
Tax number (NL, B):
  x For Belgium and the Netherlands the tax number for patient address and second address are now activated.
Patient address: BSN (personal tax number)
2nd address: BTW (Tax.ID number business)
     
   
Postcode (IRL):
  x Postcode fields added for Ireland.
     

8.0

8.1

Glasses

Eye examination management
x

Automatic data acceptance and prisms initialisation R -> L now also for near refraction and delivery values.

     
Dominant eye
  x

Dominant eye in patient card file is no longer reset if the entry is deleted in the order.

     

8.0

8.1

EPoS

Receipt printing (Italy)
  x

The patient's tax number is now included in the fiscal-printer receipt.

     

8.0

8.1

Reminder

   
Patient contacts
  x

Printing and exporting of reminders can now be added in patient contacts.

     

8.0

8.1

Task Scheduler

  x

Sometimes the program crashed during an FTP-upload if the FTP-server could not be reached. Fixed. Now an error message is displayed.

     

 

Version 8.0.30.0 | 8.1.30.1 | from 14.12.2015

 

8.0

8.1

Ordering System Lenses

   
o.k.m (B2B E-Mail)
x x

New email-address order@okm-lens.de; please change in supplier master data.

     
   
General
  x

Thickness reduction for stock lenses can no longer be ordered.

     

8.0

8.1

Lens Price Lists

   
Optimeyes-Format / France
x x

Program-error during price-list loading removed.

     

8.0

8.1

Patient Card File

   
Patient details
  x If a DOB was entered with a leading zero, this sometimes led to a wrong DOB format. Error removed.
     

8.0

8.1

Online Dataservice

  x

New option 'all languages'

  x

Default settings for 'all languages' and 'all countries' can be set in the preferences.

  x

The progress bar now shows the current activity and a success message after finishing, instead of the bytes downloaded.

     

 

Version 8.0.29.0 | 8.1.29.1 | from 02.11.2015

 

8.0

8.1

Lenses Ordering System

   
Zeiss (B2B Webservice)
x x

Error messages adapted according to info from Zeiss.

     
   
Essilor (B2B Webservice)
x x

Following a request from the supplier, the distance centration point is now sent for Bifo/Trifo-lenses.

     

8.0

8.1

Patient Card File

   
Postcode
x x Postcode Portugal now 8 digits available.
     

8.0

8.1

Glasses

   
New entry with preset
x x

The delivery note number is not copied over anymore to the new entry with preset.

     

8.0

8.1

Appointments Diary

   
Holiday view
x x

Sometimes, the diary crashed when started in holiday view. Fixed.

     

8.0

8.1

Phoenix Interface

   
Patient assignment
  x

Sometimes, the program crashed during new phoenix-patient assignment. Fixed.

     

8.0

8.1

Workstation Profiles

   
Branch networking
x x

Not used for the workstation, from which the data of the profile come. The check now contains the workstation number and the branch.

     

8.0

8.1

Insurance codes

   
Insurance codes input
x x

Sometimes, the program crashed during insurance code input. Fixed.

     

8.0

8.1

System

   
Email sending
  x

Revised procedure for checking the validity of email-addresses.

     

 

Version 8.0.28.0 | 8.1.28.1 | from 24.08.2015

 

8.0

8.1

Lenses Ordering System

   
Zeiss (B2B Webservice)
x x

New ordering parameter C-Code for new lenses from 1.9.

     
   
BOW (B2B E-Mail)
x x

Glazing at lens supplier activated in ordering options.

  x

Second pair ordering now possible.

     
   
Schulz (B2B Webservice)
x x

Glazing at lens supplier activated in ordering options.

     
Hoya (Webservice)
x x

Option special material in facette window renamed to the precise designation SPX.

     

8.0

8.1

Lens Consultation Interface

Hoya HoyaiLog
  x

Special values for MyStyle V+ lenses from the Identifier are now exchanged with winIPRO via the interface and recorded in the glasses order. Thereby, ordering this lenses is now possible directly from winIPRO.

     

8.0

8.1

Appointments Diary

   
Sending appointments via Email or SMS
  x

Patient and appointment data are now shown in the preview.

     

8.0

8.1

Medmont Interface

x x

Adapted for new version Medmont 6

     

8.0

8.1

Online Data Service

   
Multiple selection
x x

If several files were marked and downloaded simultaneously, and the loading was cancelled for individual files, then none of the downloaded files were marked as already downloaded in the data service. Fixed.

     

8.0

8.1

Task Scheduler

   
Automatic local copy
  x

Local copy can now be sent to an alternative directory.

     

 

Version 8.0.27.0 | 8.1.27.1 | from 22.06.2015

 

8.0

8.1

Lenses Ordering System

   
Essilor (B2B Webservice)
x x

"Preset: Send customer name" now available in supplier master data.

     
   
R+H (B2B E-Mail, B2B Webservice, E-Mail)
x x

The ordering option preference intermediate has been deactivated. Doesn't exist anymore at the supplier's side.

     
R+H (B2B Webservice)
x x

New ordering options: Base curve demo, head tilt range, second pair ordering.

     
R+H (B2B E-Mail)
x x

Head tilt range and base curve demo have been released also for the older ordering via email.

     
R+H (B2B-XML)
x x

New ordering option: Second pair ordering.

     
X-Ramvision (B2B E-Mail)
x x

Frame finishing option released by supplier.

     
Rodenstock (B2B Webservice)
  x

Ordering option "insurance" extended.

     
Nika (B2B E-Mail)
x x

Ordering option base curve released after consultation with supplier.

     
Visall (Visall Online)
x x

New field: Progression length.

     
x x
New: Ophthalmica (B2B E-Mail)
x x
New: LuxLens (B2B E-Mail)
     

8.0

8.1

Lens Consultation Interface

OptiSwiss Osshop
Brillenprofi L1Shop
Dynoptic Dynashop
x x

Progression length field in additional order data released after consultation with the suppliers.

     
Optovision WinOnline 5
  x

Exchange format to WinOnline changed to make the exchange of the progression length possible.

     

8.0

8.1

Lens Price Lists

   
SF6-Format
x x

Support for Version 6.10.2 of SF6 price list format added.

     

8.0

8.1

Patient Card File

   
Second address
x

Mini-button for "all fields" was deactivated. Fixed.

     

8.0

8.1

Contact Lenses

   
CL-procedure complementary refraction
x x

 Stabilisisation axis empty for 0.

x x

Axis empty for cylinder 0.

     

8.0

8.1

Order Status Control

   
Glasses lenses
x x

New columns available for lenses: Progression length, external order number

     

8.0

8.1

Appointment Diary

   
Setting 'Automatic appointments check'
x x

Input of -1 now possible. In this case, no appointment check will be carried out.

     

8.0

8.1

Exam Instruments Interface

   
Rodenstock DNEye Scanner
x x

Patient-list calling up accelerated.

     

8.0

8.1

Exam Instruments Interface

x x
New: Essilor Wave Analyzer
x x
New: Visionix VX 120
     

8.0

8.1

Oculus Interface

   
All Oculus-interfaces
x x

Interfaces reprogrammed. Larger data amounts are now processed much quicker. Data have to be converted before use.

     

8.0

8.1

Data Backup

   
Automatic data backup
x x

Automatic stopping of instruments and lab device drivers now works again.

x x

For automatic data backup, the notes/error windows which require a user interaction, have been removed. Notes and error messages are now displayed via the task scheduler.

     

Version 8.0.26.0 | 8.1.26.1 | from 02.03.2015

 

8.0

8.1

Lens Ordering System

   
Zeiss Logon (Webservice)
x x

New ordering parameter: Thickness reduction prism (for Benelux: C-Code)

     
x x
New: X-Ramvision (B2B-XML)
     

8.0

8.1

Lens Consultation Interface

   
Zeiss Winfral (ISM)
x x

For the design type, Winfral doesn't distinguish between "empty" and "Balanced". Following our customers' wishes, winIPRO will now show "Balanced" in the additional order data in these cases, and not the empty entry anymore. For Zeiss, both entries are identical, as "Balanced" is the standard value if nothing has been entered.

     

8.0

8.1

Eye Exam Report

   
iProfiler / Data transfer
x x

For newer devices, the assignment 1=h, 2=v is not necessarily set as default. During data transfer, the assignment is now done accordig to axis position.

   

 

 

Version 7.4.25.0 | 8.0.25.1 | from 27.01.2015

 

7.4

8.0

Lens Ordering System

   
Zeiss Logon (Webservice)
x x

New ordering option for announced products: Thickness reduction prism.

     

7.4

8.0

Diary

   
Message sending (SMS, Email)
x x

Parameter for appointment employee now working.

   

 

 

Version 7.4.24.0 | 8.0.24.1 | from 15.12.2014

 

7.4

8.0

Lens Ordering System

   
Hoya (Webservice)
  x

Status window during ordering.

  x

Optimised communication with the Hoya-Server, makes sending of orders faster.

   

 

   
Optovision (B2B-XML)
x x

After consultations with Optovision, the fields groove width and depth have been activated for ordering frame finished lenses.

   

 

x x
New: Reize (Webservice)
x x
New: Omega Optix (Webservice)
   

 

   
BOW (Edifact via Email)
x x

The supplier cannot read the patient name transferred by winIPRO correctly anymore. Therefore, the patient name cannot be transferred anymore, unfortunately.

   

 

7.4

8.0

Contact Lenses Ordering System

   
Bausch (Webservice)
   
Johnson (Webservice)
   
MPG+E (Webservice)
   
Sauflon (Webservice)
   
Wöhlk (Webservice)
  x

Status check only for orders, which have been ordered during the last 14 days.

  x

Status window displayed during ordering and during status check.

   

 

7.4

8.0

Glasses

   
New entry / Preset
x x

For new entry with this preset, the employee is now also copied, even if the employee number is higher than 3000.

   

 

7.4

8.0

Workshop Devices

   
NIDEK Lan Protocol
x x

Low-Vision orders could not be called up at the devices. Fixed.

   

 

7.4

8.0

Preferences

   
System parameters - Functions
  x

New Option "Automatic RRP-discount". Enters automatic discounts on the basis of the difference between sales price - recommended retail price.

   

 

 

Version 7.4.23.0 | 8.0.23.1 | from 04.11.2014

 

7.4

8.0

Lens Ordering System

   
Galaxa (B2B-XML)
x x

In consultation with the lens supplier, the ordering option "object distance" has been activated.

   

 

   
Shamir (B2B-XML)
x x

New in Austria

x x

Frame finishing activated in consultation with the supplier

   

 

   
Novacel (B2B-XML)
x x

Ordering options adapted to the supplier's requests.

   

 

   
Essilor (B2B-XML)
x x

Option "Patient details for guarantee card" is now available to transfer the complete patient name to Essilor

   

 

   
Nika (B2B-XML)
x x

New fields in additional order data: Object distance, Inset

   

 

   
AVM (B2B-XML)
x x

New ordering parameters: Refraction distance near, Base curve

   

 

   
IGA Horus (B2B-XML)
x x

New ordering parameters: Refraction distance near, Initials, Design-characteristic, Inset

   

 

   
Seiko (B2B-XML), Seiko (Email)
x x

The options "Balance lens" and "Slab off" have been deactivated following a request by Seiko.

   

 

x x
New: Knecht+Müller (B2B-XML)
   

 

   
General
x x

If the mean value of the side-specific values of CVD, inclination and frames lens angle differs significantly from the side neutral field, an error message is now displayed.

   

 

7.4

8.0

Frames Ordering System

   
Opticland
x x

The files tar.exe and gpg.exe are now expected to be in the program directory. This is a workaround for a problem with some installations on Windows 2012.

   

 

7.4

8.0

Lens Consultation Interface

   
R+H Nuvola
x x

Umlauts are now transferred correctly.

   

 

   
Austrian Optic Webservice
   
Schulz Webservice
x x

The supplier informed us that some tracer formats could not be read. Now, everything is converted into one format automatically and then transferred.

   

 

   
Web portals general
x x

Sometimes, the lens name in IPRO has not been updated during data acceptance from a web portal. The relevant ordering code for the order however, was always correct. Lens name acceptance fixed.

   

 

x x
New: IGA Online
x x
New: Brillenprofi L1-Shop
x x
New: Dynoptic Dynashop
   

 

   
Zeiss WinFral (ISM)
x x

Starting of the Zeiss-program under Windows 8.x enabled. However, there may be limited functionality of the interface, as Zeiss has stopped adaptation to newer Windows versions.

   

 

7.4

8.0

Centration Interface

   
Activisu
  x

New symbol on the interface button

   

 

7.4

8.0

Patient Card File

   
Patient search
  x

List of  "last patients" extended from max. 10 to max. 25

   

 

   
Tab configuration
x x

"Delete tab" is only active if only one page is in the tab. For tabs with several pages, delete the pages first.

   

 

7.4

8.0

Glasses

   
Lens input
x x

For new workstations, the recommended setting "Only lenses from standard supply" is now the default setting for the lens input. Of course, it can be changed by the user later.

x x

Sometimes, the obligatory coating has been automatically added only for the left lens. Fixed.

   

 

   
Frames input
  x

Side-specific fields for BVD, inclination and front curvature are now always shown, independent from the supplier.

   

 

7.4

8.0

Hearing Aids

   
Form printout-Parameters
x x

For deleted hearing aids the printout has still been filled with values. Fixed.

     
   

 

7.4

8.0

List Generator

   
Patient promotion
  x

CRM-Date now avaialble as column.

   

 

7.4

8.0

Diary

   
Week view
x x

MS Windows sometimes switched the Diary to inactive temporarily ("Program not responding"), if the network was slow and many appointments had to be loaded into the week view. Fixed.

   

 

   
Email sending
x x

Sending an appointment by email created an invalid format. Fixed.

   

 

7.4

8.0

Eye Exam Report - Instruments Interface

x x
New: Essilor APH5000
x x
New: Topcon CV5000S
     

7.4

8.0

Workstation Profile

   
Preferences
  x

In the workstation master data only the profile of the own workstation could be edited, not those of the others. Fixed.

   

 

7.4

8.0

Reminder

   
Preferences
x x

During setting up of new reminder groups only the periods could be saved, the assigned forms only the next time it was opened. Fixed.

x x

Newly created reminder groups were not instantly visible in the survey. Fixed.

   

 

7.4

8.0

Online Dataservice

  x

In the "News" section you will now find the new additions from the last 6 months instead of the last 3 months.

  x

The list in the "News" section is now sorted by release date.

  x

A warning note is displayed, if the selected download requires a newer version of winIPRO than the one you are currently using.

  x

New section for 'Individual data', mouse-over tool-tip added.

  x

Download didn't work with some Proxy-Servers. Workaround added.

   

 

7.4

8.0

Master Data

   
Suppliers
  x

Only the first 8 characters of the customer number at the supplier were saved. Fixed.

  x

Lens-/CL-suppliers with an ordering system, for which no symbol has been avaialble, have now received a symbol for the button. Total of 24 new supplier symbols added.

   

 

7.4

8.0

Preferences

   
Internet parameters
  x

Internet access: Proxy for FTP can now be configured.

  x

Proxy-authentification for HTTP is now supported.

  x

A Socks-Proxy can now be used for HTTP.

  x

Internet access: Test-connection button for Email access data

   

 

7.4

8.0

Diagnosis

   
Event protocol
  x

Event protocol can now be saved on any data medium.

   

 

7.4

8.0

Main Menu

  x

The menu item "Data backup - Restore" has been moved to the Diagnosis part, to prevent unintended restores.

   

 

7.4

8.0

System

x x

Extended winIPRO-version number with publication-ID ('PubID')

   

 

 


 

Archive: Here you will find previous version infos